Publications by authors named "A Fenu"

A liquid-phase nitrous oxide sensor can be used as a proxy to estimate the gas emissions. Experiments conducted in a pilot-scale Anammox reactor, at different degrees of aeration intermittency, indicate a predictive error in the range of 13.4-19.

View Article and Find Full Text PDF

Ultraviolet radiation (UV)-activated peroxydisulfate (PDS) and peroxymonosulfate (PMS) advanced oxidation processes were examined for their capacity to remove nine pharmaceutically active compounds (PhACs) from secondary effluent. The effect of operational parameters (initial oxidant concentration, UV exposure time, pH, common coexisting anions and effluent organic matter (EfOM)) on UV/PDS and UV/PMS treatment efficiency was investigated in a collimated beam device housing a low-pressure mercury UV lamp emitting light at 253.7 nm.

View Article and Find Full Text PDF

Membrane bioreactors (MBRs) augmented with terrestrial white-rot basidiomycetes have already been tested for the removal of pharmaceutically active compounds (PhACs) from wastewaters. Within the present study, an aquatic ascomycete ( sp.) was initially demonstrated to efficiently remove several PhACs at their real environmental trace concentrations from nonsterile municipal wastewater on a laboratory scale.

View Article and Find Full Text PDF

Through their release of effluents, conventional wastewater treatment plants (WWTPs) represent a major pollution point sources for pharmaceutically active compounds (PhACs) in water bodies. The combination of a biological activated carbon (BAC) filter coupled with an ultrafiltration (UF) unit was evaluated as an advanced treatment for PhACs removal at pilot scale. The BAC-UF pilot plant was monitored for one year.

View Article and Find Full Text PDF

Previous studies demonstrated that pain induced by a noxious stimulus during a distraction task is affected by both stimulus-driven and goal-directed processes which interact and change over time. The purpose of this exploratory study was to analyse associations of aspects of subjective pain experience and engagement with the distracting task with attention-sensitive components of noxious laser-evoked potentials (LEPs) on a single-trial basis. A laser heat stimulus was applied to the dorsum of the left hand while subjects either viewed the Rubin vase-face illusion (RVI), or focused on their pain and associated somatosensory sensations occurring on their stimulated hand.

View Article and Find Full Text PDF