Background: Total ankle arthroplasty (TAA) has become increasingly popular in the treatment for end-stage ankle arthritis in recent decades. However, there is limited evidence regarding the long-term clinical outcomes and complication rates of modern TAA implants.
Methods: This study presents a follow-up on a previous cohort involving 78 patients (81 ankles) who underwent Salto Talaris fixed-bearing TAA to treat end-stage arthritis, with a mean postoperative follow-up of 5.
Purpose: The purpose of this study was to compare the biomechanics of 4-strand and 5-strand hamstring constructs for anterior cruciate ligament grafts.
Methods: Thirty-six human cadaveric hamstring grafts were tested in 3 different conditions: (1) graft femoral fixation complex, (2) graft femoral and tibial fixation (GFTF) complex using a human model, and (3) GFTF complex using a porcine model. Grafts were tested on a tensile testing machine.