Publications by authors named "A Bouguecha"

Advanced manufacturing techniques aimed at implants with high dependability, flexibility, and low manufacturing costs are crucial in meeting the growing demand for high-quality products such as biomedical implants. Incremental sheet forming is a promising flexible manufacturing approach for rapidly prototyping sheet metal components using low-cost tools. Titanium and its alloys are used to shape most biomedical implants because of their superior mechanical qualities, biocompatibility, low weight, and great structural strength.

View Article and Find Full Text PDF

Background: We applied a previously established and validated numerical model to a novel short-stemmed implant for a 'pre-launch' investigation.

Methods: The implant system consists of two different implant geometries for valgus/varus-positioned proximal femurs with differences in volume distribution, head/neck angle, and calcar alignment. The aim of the design was to achieve a better adaption to the anatomic conditions, resulting in a favourable load transfer.

View Article and Find Full Text PDF

Background: The history of total ankle arthroplasty (TAA) has different evolution steps to improve the outcome. The third generation implants show an overall 8-year survival rate up to 93%. The main reported reason for early failure of TAA is aseptic loosening, cyst formation is also frequently reported.

View Article and Find Full Text PDF

We developed a numerical model to describe the bone remodeling process in periprosthetic bone tissues and validated it by means of dual energy X-ray absorptiometry methods with different types of hip implants. In this paper, we applied the numerical model to investigate the influence of implant size and of the size of the porous coated area on bone remodeling in a periprosthetic human femur in an effort to define properties of implants, which would reduce bone remodeling after total hip arthroplasty. Two different sizes of a newly designed implant and three different coating area sizes were investigated in this paper.

View Article and Find Full Text PDF

Background: Aseptic loosening due to bone remodelling processes after total hip replacement is one common cause for revision surgery. In human medicine, dual-energy X-ray absorptiometry (DEXA) is the gold standard for quantitative evaluation of bone mineral density, whereas in veterinary medicine conventional radiography is used for follow-up studies. Recently, a method has been described using digital X-ray images for quantitative assessment of grey scale values of bone contrast.

View Article and Find Full Text PDF