Introduction: The Medical Devices Committee (CODIMS) of the Assistance publique-Hôpitaux de Paris (AP-HP) is responsible for deciding whether innovative and costly sterile medical devices (SMD) should be adopted for the AP-HP network and for issuing recommendations on their proper use. The aim of this study was to qualify retrospectively the level of evidence of clinical studies used for the device evaluations by the CODIMS in 2012 and 2013 and to analyze the relationship between levels of evidence and decisions.
Material And Method: Executive summaries written in 2012 and 2013 about studied SMD was analyzed and the level of evidence of clinical studies used was qualified in high/low levels of evidence according to the scale of Sackett et al.
Background: At the hospital level, decisions about purchasing new and oftentimes expensive medical devices must take into account multiple criteria simultaneously. Multi-criteria decision analysis (MCDA) is increasingly used for health technology assessment (HTA). One of the most successful hospital-based HTA approaches is mini-HTA, of which a notable example is the Matrix4value model.
View Article and Find Full Text PDFRationale, Aims And Objectives: Like health technology assessment (HTA) agencies, hospitals are faced with requests for innovative and costly medical devices. However, local decision makers are frequently confronted with a lack of high-quality clinical data when assessing the effectiveness of innovative medical devices. The aim of this study was to quantify the level of evidence available for innovative medical devices in the context of hospital-based HTA.
View Article and Find Full Text PDFThe A/Z dependence of projectile fragmentation at relativistic energies has been studied with the ALADIN forward spectrometer at SIS. A stable beam of (124)Sn and radioactive beams of (124)La and (107)Sn at 600 MeV per nucleon have been used in order to explore a wide range of isotopic compositions. Chemical freeze-out temperatures are found to be nearly invariant with respect to the A/Z of the produced spectator sources, consistent with predictions for expanded systems.
View Article and Find Full Text PDFThe spallation of 56Fe in collisions with hydrogen at 1A GeV has been studied in inverse kinematics with the large-aperture setup SPALADIN at GSI. Coincidences of residues with low-center-of-mass kinetic energy light particles and fragments have been measured allowing the decomposition of the total reaction cross section into the different possible deexcitation channels. Detailed information on the evolution of these deexcitation channels with excitation energy has also been obtained.
View Article and Find Full Text PDF