Publications by authors named "A Boczkowski"

Though potentially beneficial, proton beam stereotactic radiosurgery has not been adopted widely secondary to the technical challenge of safely delivering multiple focused beams of proton radiation. In this study, we describe the design and characterization of a proton beam stereotactic radiosurgery system that can be adopted by existing passive scattering systems. This system utilizes a helmet-like device in which patient-specific brass apertures required for final beam collimation are positioned on a scaffold that is separate from the treatment gantry.

View Article and Find Full Text PDF

The Elekta Unity MR-linac utilizes daily magnetic resonance imaging (MRI) for online plan adaptation. In the Unity workflow, adapt to position (ATP) and adapt to shape (ATS) treatment planning options are available which represent a virtual shift or full re-plan with contour adjustments respectively. Both techniques generate a new intensity modulated radiation therapy (IMRT) treatment plan while the patient lies on the treatment table and thus adapted plans cannot be measured prior to treatment delivery.

View Article and Find Full Text PDF

For many patients, stereotactic radiosurgery (SRS) offers a minimally invasive, curative option when surgical techniques are not possible. To date, the literature supporting the efficacy and safety of SRS treatment techniques uses photon beams. However, with the number of proton therapy facilities exponentially growing and the favorable physical properties of proton beam radiation therapy, there is an opportunity to develop proton therapy techniques for SRS.

View Article and Find Full Text PDF

MR image-guided radiotherapy has the potential to improve patient care, but integration of an MRI scanner with a linear accelerator adds complexity to the commissioning process. This work describes a single institution experience of commissioning an Elekta Unity MR-linac, including mechanical testing, MRI scanner commissioning, and dosimetric validation. Mechanical testing included multileaf collimator (MLC) positional accuracy, measurement of radiation isocenter diameter, and MR-to-MV coincidence.

View Article and Find Full Text PDF

Recent availability of MRI-guided linear accelerators has introduced a number of clinical challenges, particularly in the context of online plan adaptation. Paramount among these is verification of plan quality prior to patient treatment. Currently, there are no commercial products available for monitor unit verification that fully support the newly FDA cleared Elekta Unity 1.