Publications by authors named "A Ardagil"

The purpose of this study is to compare the efficacy and safety of 577-nm subthreshold micropulse laser (SML) and intravitreal bevacizumab injection (IVB) combined therapy with IVB monotherapy in the treatment of diabetic macular edema (DME). This retrospective study included 80 eyes of 80 patients; 40 eyes were treated with IVB monotherapy, and 40 eyes were treated with SML-IVB combined therapy. The mean number of required IVB injections and changes of best corrected visual acuity (BCVA) and central macular thickness (CMT) values were compared between the groups.

View Article and Find Full Text PDF

Purpose: To compare the efficacy and safety of subthreshold micropulse laser treatment (SML), standard-fluence photodynamic therapy (PDT) and low-fluence PDT in patients with chronic central serous chorioretinopathy (cCSC).

Methods: This retrospective study included 52 eyes of 46 patients with chronic CSC who were treated with 577nm SML (n=23), standard-fluence PDT (verteporfin 6mg/m and light energy 50J/cm) (n=13), or low-fluence PDT (verteporfin 6mg/m and light energy 25J/cm) (n=16). The mean changes in best-corrected visual acuity (BCVA) and optical coherence tomography (OCT) parameters, including central retinal thickness (CRT), subretinal fluid (SRF) height, and ellipsoid zone (EZ) disruption, over the follow-up period were evaluated.

View Article and Find Full Text PDF

Purpose: To compare the efficacy and safety of half-dose vs. half-fluence vs. standard photodynamic therapy (PDT) in patients with chronic central serous chorioretinopathy (cCSC).

View Article and Find Full Text PDF

We describe a combined technique of trocar-assisted sutureless scleral-fixated intraocular lens implantation and silicone oil injection at the same session. Two 3 mm scleral tunnels were created 2 mm away from and parallel to the limbus with the 23-gauge vitrectomy trocars entering the sclera transconjunctivally at an angle of approximately 10° at the 3 o'clock and 9 o'clock meridians. After the 3-piece foldable IOL was delivered to the anterior chamber through the corneal incision, the tip of one of the IOL haptics was grasped with a 23-gauge serrated retinal forceps entered through the trocar located at the 3 o'clock meridian.

View Article and Find Full Text PDF

Background: Alström syndrome is a rare autosomal recessive inherited disorder caused by mutations in the ALMS1 gene.

Methods: We describe the clinical and five novel mutational screening findings in six patients with Alström syndrome from five families in a single center with distinct clinical presentations of this condition.

Results: Five novel mutations in ALMS1 in exon 8 and intron 17 were identified, one of them was a compound heterozygous: c.

View Article and Find Full Text PDF