Purpose: The purpose of this study was to develop a predictive model to evaluate pretreatment patient-specific quality assurance (QA) based on treatment planning parameters for stereotactic body radiation therapy (SBRT) for liver carcinoma.
Materials And Methods: We retrospectively selected 180 cases of liver SBRT treated using the volumetric modulated arc therapy technique. Numerous parameters defining the plan complexity were calculated from the DICOM-RP (Radiotherapy Plan) file using an in-house program developed in MATLAB.