The LIULIN-3M instrument is a further development of the LIULIN dosimeter-radiometer, used on the MIR spacestation during the 1988-1994 time period. The LIULIN-3M is designed for continuous monitoring of the radiation environment during the BION-12 satellite flight in 1999. A semiconductor detector with 1 mm thickness and cm2 area is contained in the instrument.
View Article and Find Full Text PDFRadiation impact of the SPEs on board the MIR space station and in the interplanetary space is discussed in the report. The data of the on-board radiation dosimeter R-16 were used to measure the SPE absorbed doses. Some of SPEs (such as September-October 1989 series of very large SPEs) were measured in detail by Liulin active high sensitive dosimetric instrument installed on board MIR station.
View Article and Find Full Text PDFMeasurements on board the MIR space station by the Bulgarian-Russian dosimeter LIULIN have been used to study the solar cycle variations of the radiation environment. The fixed locations of the instrument in the MIR manned compartment behind 6-15 g/cm2 of shielding have given homogeneous series of particle fluxes and doses measurements to be collected during the declining phase of 22nd solar cycle between September 1989 and April 1994. During the declining phase of 22nd solar cycle the GCR (Galactic Cosmic Rays) flux observed at L>4 (where L is the McIlwain parameter) has enhanced from 0.
View Article and Find Full Text PDFIn March 1991 the CRRES spacecraft measured a new transient radiation belt resulting from a solar proton event and subsequent geomagnetic disturbance. The presence of this belt was also noted by dosimeter-radiometers aboard the Mir space station (approx. 400 km, 51 degrees orbit) and by particle telescopes on the NOAA-10 spacecraft (850 km, 98 degrees).
View Article and Find Full Text PDFMeasurements on board the Mir space station have been used to study the dose rate and the particle flux distribution in the inner magnetosphere. The measurements have been performed with the Bulgarian-Russian dosimeter-radiometer Liulin. The paper concentrates on the dynamics of the observed "new" and "second" maxima which were created after Solar Proton Events (SPE) in the 1989-1994 time.
View Article and Find Full Text PDFRadiation risk on a future long-duration manned space mission appears to be one of the basic factors in planning and designing the mission. Since 1988 different active dosimetric investigations has been performed on board the MIR space station by the Bulgarian-Russian dosimeter-radiometer LIULIN and French tissue-equivalent proportional counters CIRCE and NAUSICAA. A joint French-Bulgarian-Russian dosimetry experiment and the dosimetry-radiometry system RADIUS-MD have been developed for the future MARS-96 mission.
View Article and Find Full Text PDFSince 1988 high sensitivity semiconductor dosimeter-radiometer "Liulin" worked on board of MIR space station. Device measured the absorbed dose rate and the flux of penetrating particles. The analysis of the data shows the following new results: In October 1989 and after March 24, 1991, two additional stable maximums in flux channel were observed in the southern-eastern part of South Atlantic Anomaly (SAA).
View Article and Find Full Text PDFThe Liulin dosimeter-radiometer on the MIR space station detected the 19 October 1989 high energy solar proton event. These results show that the main particle increase contains protons with energies up to about 9 GeV. After the main particle onset the Liulin dosimeter observed a typical geomagnetic cutoff modulation of the dose rate from the solar particles as the MIR space station traversed magnetic latitudes.
View Article and Find Full Text PDFFlux and dose rate dynamics of solar cosmic rays were measured by the Lyulin dosimeter during the events 19 October 1989 and 23 March 1991. The maximum dose rate registered was 0.4, 0.
View Article and Find Full Text PDFUsing data from dosimetry-radiometry system "Liulin" on board of "Mir"-space station the particle flux and doserate during September-October, 1989 has been studied. The orbit of the station was 379 km perigee, 410 km apogee and 51.6 degrees inclination.
View Article and Find Full Text PDFAn experiment involving active detection of space radiation was carried out in the Space Research Institute (SRI) of Bulgarian Academy of Sciences, in preparation of the flight of the second Bulgarian cosmonaut. The radiations that would be encountered on the flight were modelled including solar and galactic cosmic rays and the particle radiation in the Earth's radiation belts. The dose rate was calculated for these different radiations behind the shielding of the space station.
View Article and Find Full Text PDFA dosimetry-radiometry system has been developed at the Space Research Institute of the Bulgarian Academy of Science to measure the fluxes and dose rates on the flight of the second Bulgarian cosmonaut. The dosimetry system is designed for monitoring the different space radiations, such as solar cosmic rays, galactic cosmic rays and trapped particles in the earth radiation belts. The system consists of a battery operated small size detector unit and a "read-write" and telemetry microcomputer unit.
View Article and Find Full Text PDF