Publications by authors named "Chiwan Koo"

This paper proposes to remotely estimate a human subject's blood pressure using a millimeter-wave radar system. High blood pressure is a critical health threat that can lead to diseases including heart attacks, strokes, kidney disease, and vision loss. The commonest method of measuring blood pressure is based on a cuff that is contact-based, non-continuous, and cumbersome to wear.

View Article and Find Full Text PDF

Shiga toxin (Stxs)-producing enterohaemorrhagic (EHEC) and serotype 1 are major causative agents of severe bloody diarrhea (known as hemorrhagic colitis) and hemolytic uremic syndrome (HUS) associated with extraintestinal complications such as acute renal failure and neurologic impairment in infected patients under 9 years of age. Extreme nephrotoxicity of Stxs in HUS patients is associated with severe outcomes, highlighting the need to develop technologies to detect low levels of the toxin in environmental or food samples. Currently, the conventional polymerase chain reaction (PCR) or immunoassay is the most broadly used assay to detect the toxin.

View Article and Find Full Text PDF

Research has shown that pulse transit time (PTT), which is the time delay between the electrocardiogram (ECG) signal and the signal from a photoplethysmogram (PPG) sensor, can be used to estimate systolic blood pressure (SBP) and diastolic blood pressure (DBP) without the need for a cuff. However, the LED of the PPG sensor requires the precise adjustment of both light intensity and light absorption rates according to the contact status of the light-receiving element. This results in the need for regular calibration.

View Article and Find Full Text PDF

This paper presents a silicon-dioxide-coated capacitive electrode system for an ambulatory electrocardiogram (ECG). The electrode was coated with a nano-leveled (287 nm) silicon dioxide layer which has a very high resistance of over 200 MΩ. Due to this high resistance, the electrode can be defined as only a capacitor without a resistive characteristic.

View Article and Find Full Text PDF

A miniaturized pump to manipulate liquid flow in microchannels is the key component of microfluidic devices. Many researchers have demonstrated active microfluidic pumps, but most of them still required additional large peripherals to operate their micropumps. In addition, those micropumps were made of polymer materials so that their application may be limited to a variety of fields that require harsh conditions at high pressures and temperatures or organic solvents and acid/base.

View Article and Find Full Text PDF

This study proposes a rapid and inexpensive thermocycler that enables rapid heating of samples using a thin glass chip and a cheap chip resistor to overcome the on-site diagnostic limitations of polymerase chain reaction (PCR). Microchip PCR devices have emerged to miniaturize conventional PCR systems and reduce operation time and cost. In general, PCR microchips require a thin-film heater fabricated through a semiconductor process, which is a complicated process, resulting in high costs.

View Article and Find Full Text PDF

The performance of micromixers, namely their mixing efficiency and throughput, is a critical component in increasing the overall efficiency of microfluidic systems (e.g., lab-on-a-chip and μ-TAS).

View Article and Find Full Text PDF

We developed a stand-alone, real-time optical detection device capable of reading fluorescence intensities from cell samples with high sensitivity and precision, for use as a portable fluorescent sensor for sensing fluorescently labeled enterohemorrhagic Escherichia coli (EHEC) Shiga toxins (Stxs). In general, the signal intensity from the fluorescently labeled Stxs was weak due to the small number of molecules bound to each cell. To address this technical challenge, we used a highly sensitive light detector (photomultiplier tube: PMT) to measure fluorescence, and designed a portable optical housing to align optical parts precisely; the housing itself was fabricated on a 3D printer.

View Article and Find Full Text PDF

We propose a new packaging process for an implantable blood pressure sensor using ultrafast laser micro-welding. The sensor is a membrane type, passive device that uses the change in the capacitance caused by the membrane deformation due to applied pressure. Components of the sensor such as inductors and capacitors were fabricated on two glass (quartz) wafers and the two wafers were bonded into a single package.

View Article and Find Full Text PDF

We present a rapid and highly reliable glass (fused silica) microfluidic device fabrication process using various laser processes, including maskless microchannel formation and packaging. Femtosecond laser assisted selective etching was adopted to pattern microfluidic channels on a glass substrate and direct welding was applied for local melting of the glass interface in the vicinity of the microchannels. To pattern channels, a pulse energy of 10 μJ was used with a scanning speed of 100 mm/s at a pulse repetition rate of 500 kHz.

View Article and Find Full Text PDF

It has been recently known that not only the presence of inhibitory molecules associated with myelin but also the reduced growth capability of the axons limit mature central nervous system (CNS) axonal regeneration after injury. Conventional axon growth studies are typically conducted using multi-well cell culture plates that are very challenging to investigate localized effects of drugs and limited to low throughput. Unfortunately, there is currently no other tools that allow investigating localized axonal responses to biomolecules in high-throughput for screening potential drugs that might promote axonal growth.

View Article and Find Full Text PDF

The loss of urinary bladder control/sensation, also known as urinary incontinence (UI), is a common clinical problem in autistic children, diabetics, and the elderly. UI not only causes discomfort for patients but may also lead to kidney failure, infections, and even death. The increase of bladder urine volume/pressure above normal ranges without sensation of UI patients necessitates the need for bladder sensors.

View Article and Find Full Text PDF

Detecting and quantifying extremely low concentrations of oil from the environment have broad applications in oil spill monitoring in ocean and coastal areas as well as in oil leakage monitoring on land. Currently available methods for low-concentration oil detection are bulky or costly with limited sensitivities. Thus they are difficult to be used as portable and field-deployable detectors in the case of oil spills or for monitoring the long-term effects of dispersed oil on marine and coastal ecosystems.

View Article and Find Full Text PDF

Rapid and accurate detection of plant pathogens in the field is crucial to prevent the proliferation of infected crops. Polymerase chain reaction (PCR) process is the most reliable and accepted method for plant pathogen diagnosis, however current conventional PCR machines are not portable and require additional post-processing steps to detect the amplified DNA (amplicon) of pathogens. Real-time PCR can directly quantify the amplicon during the DNA amplification without the need for post processing, thus more suitable for field operations, however still takes time and require large instruments that are costly and not portable.

View Article and Find Full Text PDF

Magnetic resonance (MR) microscopy typically employs microcoils for enhanced local signal-to-noise ratio (SNR). Planar (surface) microcoils, in particular, offer the potential to be configured into array elements as well as to enable the imaging of extremely small samples because of the uniformity and precision provided by microfabrication techniques. Microcoils, in general, however, are copper-loss dominant, and cryocooling methods have been successfully used to improve the SNR.

View Article and Find Full Text PDF

We report a ratiometric temperature imaging method based on Mn luminescence from Mn-doped CdS-ZnS nanocrystals (NCs) with controlled doping location, which is designed to exhibit strong temperature dependence of the spectral lineshape while being insensitive to the surrounding chemical environment. Ratiometric thermometry on the Mn luminescence spectrum was performed by using Mn-doped CdS-ZnS core-shell NCs that have a large local lattice strain on the Mn site, which results in the enhanced temperature dependence of the bandwidth and peak position. The Mn luminescence spectral lineshape is highly robust with respect to the change in the polarity, phase and pH of the surrounding medium and aggregation of the NCs, showing great potential in temperature imaging under chemically heterogeneous environment.

View Article and Find Full Text PDF

A microfluidic device that simultaneously applies the conditions required for microelectroporation and microsonoporation in a flow-through scheme toward high-efficiency and high-throughput molecular delivery into mammalian cells is presented. This multi-modal poration microdevice using simultaneous application of electric field and ultrasonic wave was realized by a three-dimensional (3D) microelectrode scheme where the electrodes function as both electroporation electrodes and cell flow channel so that acoustic wave can be applied perpendicular to the electric field simultaneously to cells flowing through the microfluidic channel. This 3D microelectrode configuration also allows a uniform electric field to be applied while making the device compatible with fluorescent microscopy.

View Article and Find Full Text PDF

We present the development of a microfluidically cryo-cooled planar coil for magnetic resonance (MR) microscopy. Cryogenically cooling radiofrequency (RF) coils for magnetic resonance imaging (MRI) can improve the signal to noise ratio (SNR) of the experiment. Conventional cryostats typically use a vacuum gap to keep samples to be imaged, especially biological samples, at or near room temperature during cryo-cooling.

View Article and Find Full Text PDF