This article presents a high-frequency application-specific integrated circuit (ASIC) transceiver for an ultrasound imaging system designed with a focus on low complexity. To simplify the design, it employs a conventional Class-D power amplifier structure for the transmitter (TX) and a resistive feedback transimpedance amplifier (TIA), which consists of a common-source amplifier followed by a source follower for the receiver (RX). Through careful optimization, the RX achieves a measured transimpedance gain of 90 dBΩ and an input-referred noise of 5.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
October 2024
This paper presents a reconfigurable bidirectional wireless power and data transceiver (RB-WPDT) integrated circuit (IC) for wearable biomedical applications. The proposed transceiver can be reconfigured as a differential class-D power amplifier or a full-wave rectifier depending on the mode signal to facilitate power transfer between devices. Additionally, the RBWPDT system supports full-duplex (FD) data transmission via a single inductive link, enabling real-time control and monitoring between devices.
View Article and Find Full Text PDFWireless modules that provide telecommunications and power-harvesting capabilities enabled by radio-frequency (RF) electronics are vital components of skin-interfaced stretchable electronics. However, recent studies on stretchable RF components have demonstrated that substantial changes in electrical properties, such as a shift in the antenna resonance frequency, occur even under relatively low elastic strains. Such changes lead directly to greatly reduced wireless signal strength or power-transfer efficiency in stretchable systems, particularly in physically dynamic environments such as the surface of the skin.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
August 2024
Active implantable medical devices (AIMDs) rely on batteries for uninterrupted operation and patient safety. Therefore, it is critical to ensure battery safety and longevity. To achieve this, constant current/constant voltage (CC/CV) methods have been commonly used and research has been conducted to compensate for the effects of built-in resistance (BIR) of batteries.
View Article and Find Full Text PDFWhen it is necessary to detect various physiological signals of the human body, clothing embroidered with near-field effect patterns can be used as a long-term power supply medium to supply power to long-distance transmitters and receivers to form a wireless power supply system. The proposed system uses an optimized parallel circuit to achieve a power transfer efficiency of more than five times higher than that of the existing series circuit. The power transfer efficiency of simultaneously supplying energy to multiple sensors is increased higher than five times and even more when only one sensor is coupled.
View Article and Find Full Text PDFFull-duplex (FD) enabled wireless power transfer (WPT) system via textile for miniaturized IMD is presented. By utilizing the battery-free near-field communication (NFC) method, the system realizes wireless power and data transmission without a bulky battery or energy harvester which can diminish the physical size of implantable medical device (IMD). Moreover, using textile as a medium of power transmission, the system overcomes the drawback and extends the limited effective range of the NFC method.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
December 2019
To eliminate tethering effects on the small animals' behavior during electrophysiology experiments, such as neural interfacing, a robust and wideband wireless data link is needed for communicating with the implanted sensing elements without blind spots. We present a software-defined radio (SDR) based scalable data acquisition system, which can be programmed to provide coverage over standard-sized or customized experimental arenas. The incoming RF signal with the highest power among SDRs is selected in real-time to prevent data loss in the presence of spatial and angular misalignments between the transmitter (Tx) and receiver (Rx) antennas.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
August 2019
This paper presents a mm-sized, free-floating, wirelessly powered, implantable optical stimulation (FF-WIOS) device for untethered optogenetic neuromodulation. A resonator-based three-coil inductive link creates a homogeneous magnetic field that continuously delivers sufficient power (>2.7 mW) at an optimal carrier frequency of 60 MHz to the FF-WIOS in the near field without surpassing the specific absorption rate limit, regardless of the position of the FF-WIOS in a large brain area.
View Article and Find Full Text PDFHybrid heterostructures are essential for functional device systems. The advent of 2D materials has broadened the material set beyond conventional 3D material-based heterostructures. It has triggered the fundamental investigation and use in applications of new coupling phenomena between 3D bulk materials and 2D atomic layers that have unique van der Waals features.
View Article and Find Full Text PDFIEEE Trans Circuits Syst II Express Briefs
July 2018
An adaptive averaging low noise analog front-end (AFE) is presented for central and peripheral nerve recording applications. The proposed topology allows users to trade off, on the fly, between input referred noise and the number of channels via averaging. The new low noise amplifier (LNA) utilizes a complementary doubled input transconductance ( ) topology to effectively increase the noise efficiency factor (NEF) without chopping or use of a costly BiCMOS process.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
April 2019
An inductively-powered wireless integrated neural recording and stimulation (WINeRS-8) system-on-a-chip (SoC) that is compatible with the EnerCage-HC2 for wireless/battery-less operation has been presented for neuroscience experiments on freely behaving animals. WINeRS-8 includes a 32-ch recording analog front end, a 4-ch current-controlled stimulator, and a 434 MHz on - off keying data link to an external software- defined radio wideband receiver (Rx). The headstage also has a bluetooth low energy link for controlling the SoC.
View Article and Find Full Text PDFObjective: We have developed a wireless opto-electro interface (WOENI) device, which combines electrocorticogram (ECoG) recording and optical stimulation for bi-directional neuromodulation on small, freely behaving animals, such as rodents.
Approach: The device is comprised of two components, a detachable headstage and an implantable polyimide-based substrate. The headstage establishes a bluetooth low energy (BLE) bi-directional data communication with an external custom-designed USB dongle for receiving user commands and optogenetic stimulation patterns, and sending digitalized ECoG data.
A new study with rat sciatic nerve model for peripheral nerve interfacing is presented using a fully-implanted inductively-powered recording and stimulation system in a wirelessly-powered standard homecage that allows animal subjects move freely within the homecage. The Wireless Implantable Neural Recording and Stimulation (WINeRS) system offers 32-channel peripheral nerve recording and 4-channel current-controlled stimulation capabilities in a 3 × 1.5 × 0.
View Article and Find Full Text PDFIEEE Trans Ind Electron
February 2018
This paper presents the design procedure for a new multi-cycle resonance-based voltage boosting rectifier (MCRR) capable of delivering a desired amount of power to the load (PDL) at a designated high voltage (HV) through a loosely-coupled inductive link. This is achieved by shorting the receiver (Rx) LC-tank for several cycles to harvest and accumulate the wireless energy in the RX inductor before boosting the voltage by breaking the loop and transferring the energy to the load in a quarter cycle. By optimizing the geometries of the transmitter (Tx) and Rx coils and the number of cycles, , for energy harvesting, through an iterative design procedure, the MCRR can achieve the highest PDL under a given set of design constraints.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
August 2016
To understand the complex correlations between neural networks across different regions in the brain and their functions at high spatiotemporal resolution, a tool is needed for obtaining long-term single unit activity (SUA) across the entire brain area. The concept and preliminary design of a distributed free-floating wireless implantable neural recording (FF-WINeR) system are presented, which can enabling SUA acquisition by dispersedly implanting tens to hundreds of untethered 1 mm3 neural recording probes, floating with the brain and operating wirelessly across the cortical surface. For powering FF-WINeR probes, a 3-coil link with an intermediate high-Q resonator provides a minimum S21 of -22.
View Article and Find Full Text PDFThis paper proposes three coordination laws for optimal energy generation and distribution in energy network, which is composed of physical flow layer and cyber communication layer. The physical energy flows through the physical layer; but all the energies are coordinated to generate and flow by distributed coordination algorithms on the basis of communication information. First, distributed energy generation and energy distribution laws are proposed in a decoupled manner without considering the interactive characteristics between the energy generation and energy distribution.
View Article and Find Full Text PDFIEEE Trans Ind Electron
August 2016
This paper presents a new method, called multi-cycle Q-modulation, which can be used in wireless power transmission (WPT) to modulate the quality factor (Q) of the receiver (Rx) coil and dynamically optimize the load impedance to maximize the power transfer efficiency (PTE) in two-coil links. A key advantage of the proposed method is that it can be easily implemented using off-the-shelf components without requiring fast switching at or above the carrier frequency, which is more suitable for integrated circuit design. Moreover, the proposed technique does not need any sophisticated synchronization between the power carrier and Q-modulation switching pulses.
View Article and Find Full Text PDFObjective: To evaluate whether the presence of lumbosacral transitional vertebrae (LSTV) affects the clinical outcomes of microdiscectomy (MD) in young adults with lumbar disc herniation.
Methods: We retrospectively included 398 patients who were followed-up for at least 2 years after MD for lumbar disc herniation at L4/5 (disc above the LSTV). The patients were divided into 2 groups.
IEEE J Solid-State Circuits
December 2015
A fully-integrated power management ASIC for efficient inductive power transmission has been presented capable of automatic load transformation using a method, called Q-modulation. Q-modulation is an adaptive scheme that offers load matching against a wide range of loading ( ) and coupling distance ( ) variations in inductive links to maintain high power transfer efficiency (PTE). It is suitable for inductive powering implantable microelectronic devices (IMDs), recharging mobile electronics, and electric vehicles.
View Article and Find Full Text PDFAn inductively-powered wireless integrated neural recording system (WINeR-7) is presented for wireless and battery less neural recording from freely-behaving animal subjects inside a wirelessly-powered standard homecage. The WINeR-7 system employs a novel wide-swing dual slope charge sampling (DSCS) analog front-end (AFE) architecture, which performs amplification, filtering, sampling, and analog-to-time conversion (ATC) with minimal interference and small amount of power. The output of the DSCS-AFE produces a pseudo-digital pulse width modulated (PWM) signal.
View Article and Find Full Text PDFIEEE J Emerg Sel Top Power Electron
March 2016
A platform has been presented for wireless powering of receivers (Rx's) that are arbitrarily distributed over a large area. A potential application could be powering of small Rx implants, distributed over large areas of the brain. The transmitter (Tx) consists of three overlapping layers of hexagonal planar spiral coils (hex-PSC) that are horizontally shifted to provide the strongest and most homogeneous electromagnetic flux coverage.
View Article and Find Full Text PDFObjective: The purpose of this study was to figure out the radiologic findings and risk factors related to adjacent segment degeneration (ASD) after anterior cervical discectomy and fusion (ACDF) using 3-year follow-up radiography, computed tomography (CT), and magnetic resonance image (MRI).
Methods: A retrospective matched comparative study was performed for 64 patients who underwent single-level ACDF with a cage and plate. Radiologic parameters, including upper segment range of motion (USROM), lower segment range of motion (LSROM), upper segment disc height (UDH), and lower segment disc height (LDH), clinical outcomes assessed with neck and arm visual analogue scale (VAS), and risk factors were analyzed.
Objective: There have been only a few studies on surgical treatment of lumbar disc herniation (LDH) in young adults. In addition, previous studies do not provide detailed information on the surgical outcomes for young adults with LDH. The purpose of this study was to compare the outcome of transforaminal percutaneous endoscopic lumbar discectomy (PELD) and open lumbar microdiscectomy for active, young adults (age 20-25 years).
View Article and Find Full Text PDFA wirelessly powered homecage system, called the EnerCage-HC, that is equipped with multicoil wireless power transfer, closed-loop power control, optical behavioral tracking, and a graphic user interface is presented for longitudinal electrophysiology and behavioral neuroscience experiments. The EnerCage-HC system can wirelessly power a mobile unit attached to a small animal subject and also track its behavior in real-time as it is housed inside a standard homecage. The EnerCage-HC system is equipped with one central and four overlapping slanted wire-wound coils with optimal geometries to form three- and four-coil power transmission links while operating at 13.
View Article and Find Full Text PDF